Baudouin 12M55G2D3/5 vs Caterpillar 3516C
Compare Baudouin 12M55G2D3/5 and Caterpillar 3516C by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 65.65 L and 78.08 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Baudouin 12M55G2D3/5 | Caterpillar 3516C |
|---|---|---|
| Standby electrical (50 Hz) | 2,000 kWe | 2,000 kWe |
| Prime electrical (50 Hz) | 1,800 kWe | 1,825 kWe |
| Standby electrical (60 Hz) | Not listed | 2,500 kWe |
| Prime electrical (60 Hz) | Not listed | 2,250 kWe |
| Other recorded mechanical power (duty unspecified) | 2,210 kW | Not listed |
| Displacement | 65.65 L | 78.08 L |
| Configuration | V12 | V16 |
| Cylinders | 12 | 16 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | China III | U.S. EPA Tier 2 |
| Dry weight | Not listed | Not listed |
| Origin | China | United States |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Baudouin 12M55G2D3/5: Review the model record and available supporting documents
Caterpillar 3516C: Review the model record and available supporting documents
Choosing between Baudouin 12M55G2D3/5 and Caterpillar 3516C
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.