Baudouin 16M33G1750/6 vs Googol QTA12V-EG1960D
Compare Baudouin 16M33G1750/6 and Googol QTA12V-EG1960D by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 52.8 L and 64.5 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Baudouin 16M33G1750/6 | Googol QTA12V-EG1960D |
|---|---|---|
| Standby electrical (50 Hz) | Not listed | 1,760 kWe |
| Prime electrical (50 Hz) | Not listed | 1,600 kWe |
| Standby electrical (60 Hz) | 1,750 kWe | Not listed |
| Prime electrical (60 Hz) | 1,590 kWe | Not listed |
| Displacement | 52.8 L | 64.5 L |
| Configuration | V16 | V12 |
| Cylinders | 16 | 12 |
| Recorded engine speed | 1,800 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Water-Air |
| Recorded emissions classification | Unregulated | China National Stage III / Unregulated |
| Dry weight | Not listed | 5,200 kg |
| Origin | France | China |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Baudouin 16M33G1750/6: Review the model record and available supporting documents
Googol QTA12V-EG1960D: Review the model record and available supporting documents
Choosing between Baudouin 16M33G1750/6 and Googol QTA12V-EG1960D
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.