Haifeng Machinery

Baudouin 16M55G0D3/5 vs SDEC 16KTA76-G32

Compare Baudouin 16M55G0D3/5 and SDEC 16KTA76-G32 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 87.5 L and 76 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationBaudouin 16M55G0D3/5SDEC 16KTA76-G32
Standby electrical (50 Hz)2,500 kWe2,502 kWe
Prime electrical (50 Hz)2,250 kWe2,259 kWe
Standby electrical (60 Hz)Not listedNot listed
Prime electrical (60 Hz)Not listedNot listed
Other recorded mechanical power (duty unspecified)2,750 kWNot listed
Displacement87.5 L76 L
ConfigurationV16V16
Cylinders1616
Recorded engine speed1,500 RPM1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationChina IIIChina National Stage III / Unregulated
Dry weightNot listedNot listed
OriginChinaChina

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Baudouin 16M55G0D3/5: Review the model record and available supporting documents

SDEC 16KTA76-G32: Review the model record and available supporting documents

Choosing between Baudouin 16M55G0D3/5 and SDEC 16KTA76-G32

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.