Baudouin 16M55G2D2/5 vs Cummins QSK78G11
Compare Baudouin 16M55G2D2/5 and Cummins QSK78G11 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 87.5 L and 78 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Baudouin 16M55G2D2/5 | Cummins QSK78G11 |
|---|---|---|
| Standby electrical (50 Hz) | 2,500 kWe | Not listed |
| Prime electrical (50 Hz) | 2,250 kWe | Not listed |
| Standby electrical (60 Hz) | 2,640 kWe | 2,500 kWe |
| Prime electrical (60 Hz) | 2,400 kWe | 2,275 kWe |
| Other recorded mechanical power (duty unspecified) | Not listed | 2,763 kW |
| Displacement | 87.5 L | 78 L |
| Configuration | V16 | V18 |
| Cylinders | 16 | 18 |
| Recorded engine speed | 1,500 RPM | 1,800 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | U.S. EPA Tier 2 | U.S. EPA Tier 2 |
| Dry weight | Not listed | Not listed |
| Origin | France | United Kingdom |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Baudouin 16M55G2D2/5: Review the model record and available supporting documents
Cummins QSK78G11: Review the model record and available supporting documents
Choosing between Baudouin 16M55G2D2/5 and Cummins QSK78G11
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.