Baudouin 16M55G2D2/6 vs Googol QTA16V-EG2940
Compare Baudouin 16M55G2D2/6 and Googol QTA16V-EG2940 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 87.5 L and 86 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Baudouin 16M55G2D2/6 | Googol QTA16V-EG2940 |
|---|---|---|
| Standby electrical (50 Hz) | Not listed | 2,640 kWe |
| Prime electrical (50 Hz) | Not listed | 2,400 kWe |
| Standby electrical (60 Hz) | 2,640 kWe | Not listed |
| Prime electrical (60 Hz) | 2,400 kWe | Not listed |
| Other recorded mechanical power (duty unspecified) | 2,960 kW | Not listed |
| Displacement | 87.5 L | 86 L |
| Configuration | V16 | V16 |
| Cylinders | 16 | 16 |
| Recorded engine speed | 1,800 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Water-Air |
| Recorded emissions classification | U.S. EPA Tier 2 | China National Stage III / Unregulated |
| Dry weight | Not listed | 6,400 kg |
| Origin | China | China |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Baudouin 16M55G2D2/6: Review the model record and available supporting documents
Googol QTA16V-EG2940: Review the model record and available supporting documents
Choosing between Baudouin 16M55G2D2/6 and Googol QTA16V-EG2940
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.