Haifeng Machinery

Baudouin 6M12G2D3/6 vs John Deere 6068CG550

Compare Baudouin 6M12G2D3/6 and John Deere 6068CG550 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 7.47 L and 6.8 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationBaudouin 6M12G2D3/6John Deere 6068CG550
Standby electrical (50 Hz)Not listed178 kWe
Prime electrical (50 Hz)Not listed162 kWe
Standby electrical (60 Hz)180 kWe191 kWe
Prime electrical (60 Hz)150 kWe173 kWe
Other recorded mechanical power (duty unspecified)200 kWNot listed
Displacement7.47 L6.8 L
ConfigurationL6L6
Cylinders66
Recorded engine speed1,800 RPM1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationEU Stage IIIAEuro Stage V / U.S. EPA Final Tier 4
Dry weightNot listedNot listed
OriginChinaUnited States

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Baudouin 6M12G2D3/6: Review the model record and available supporting documents

John Deere 6068CG550: Review the model record and available supporting documents

Choosing between Baudouin 6M12G2D3/6 and John Deere 6068CG550

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.