Baudouin 6M16G8D3/5 vs Cummins NTA855-G1B
Compare Baudouin 6M16G8D3/5 and Cummins NTA855-G1B by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 9.6 L and 14 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Baudouin 6M16G8D3/5 | Cummins NTA855-G1B |
|---|---|---|
| Standby electrical (50 Hz) | 280 kWe | 280 kWe |
| Prime electrical (50 Hz) | 250 kWe | 250 kWe |
| Standby electrical (60 Hz) | 312 kWe | 300 kWe |
| Prime electrical (60 Hz) | 272 kWe | 275 kWe |
| Displacement | 9.6 L | 14 L |
| Configuration | L6 | L6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Euro Stage IIIA | Unregulated |
| Dry weight | Not listed | Not listed |
| Origin | France | China |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Baudouin 6M16G8D3/5: Review the model record and available supporting documents
Cummins NTA855-G1B: Review the model record and available supporting documents
Choosing between Baudouin 6M16G8D3/5 and Cummins NTA855-G1B
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.