Baudouin 6M21G1D4/5 vs Volvo Penta TAD1384VE
Compare Baudouin 6M21G1D4/5 and Volvo Penta TAD1384VE by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 12.54 L and 12.8 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Baudouin 6M21G1D4/5 | Volvo Penta TAD1384VE |
|---|---|---|
| Standby electrical (50 Hz) | 320 kWe | Not listed |
| Prime electrical (50 Hz) | 300 kWe | Not listed |
| Standby electrical (60 Hz) | Not listed | 319 kWe |
| Prime electrical (60 Hz) | Not listed | 290 kWe |
| Other recorded mechanical power (duty unspecified) | 385 kW | 343 kW |
| Displacement | 12.54 L | 12.8 L |
| Configuration | L6 | L6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | 1,500 RPM | 1,800 RPM |
| Fuel | Diesel | Diesel/HVO |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | China IV | U.S. EPA Final Tier 4 |
| Dry weight | Not listed | Not listed |
| Origin | China | Sweden |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Baudouin 6M21G1D4/5: Review the model record and available supporting documents
Volvo Penta TAD1384VE: Review the model record and available supporting documents
Choosing between Baudouin 6M21G1D4/5 and Volvo Penta TAD1384VE
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.