Baudouin 6M21G6D3/6 vs Perkins 2806FAE18TAG1
Compare Baudouin 6M21G6D3/6 and Perkins 2806FAE18TAG1 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 12.54 L and 18.1 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Baudouin 6M21G6D3/6 | Perkins 2806FAE18TAG1 |
|---|---|---|
| Standby electrical (50 Hz) | Not listed | 462 kWe |
| Prime electrical (50 Hz) | Not listed | 420 kWe |
| Standby electrical (60 Hz) | 460 kWe | Not listed |
| Prime electrical (60 Hz) | 400 kWe | Not listed |
| Other recorded mechanical power (duty unspecified) | 510 kW | 486 kW |
| Displacement | 12.54 L | 18.1 L |
| Configuration | L6 | L6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | 1,800 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | EU Stage IIIA | India CPCBIV+ |
| Dry weight | Not listed | Not listed |
| Origin | China | United States |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Baudouin 6M21G6D3/6: Review the model record and available supporting documents
Perkins 2806FAE18TAG1: Review the model record and available supporting documents
Choosing between Baudouin 6M21G6D3/6 and Perkins 2806FAE18TAG1
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.
