Baudouin 6M21G6D5/S vs Googol PTAA6L-EG490
Compare Baudouin 6M21G6D5/S and Googol PTAA6L-EG490 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 12.6 L and 14.3 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Baudouin 6M21G6D5/S | Googol PTAA6L-EG490 |
|---|---|---|
| Standby electrical (50 Hz) | 440 kWe | 440 kWe |
| Prime electrical (50 Hz) | 400 kWe | 400 kWe |
| Standby electrical (60 Hz) | 440 kWe | Not listed |
| Prime electrical (60 Hz) | 400 kWe | Not listed |
| Displacement | 12.6 L | 14.3 L |
| Configuration | L6 | L6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Air-Air |
| Recorded emissions classification | Euro Stage V | China National Stage III / Unregulated |
| Dry weight | Not listed | 1,050 kg |
| Origin | France | China |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Baudouin 6M21G6D5/S: Review the model record and available supporting documents
Googol PTAA6L-EG490: Review the model record and available supporting documents
Choosing between Baudouin 6M21G6D5/S and Googol PTAA6L-EG490
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.