Baudouin 6M21G8D0/S vs Perkins 2506C-E15TAG2
Compare Baudouin 6M21G8D0/S and Perkins 2506C-E15TAG2 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 12.54 L and 15 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Baudouin 6M21G8D0/S | Perkins 2506C-E15TAG2 |
|---|---|---|
| Standby electrical (50 Hz) | 440 kWe | 440 kWe |
| Prime electrical (50 Hz) | 400 kWe | 400 kWe |
| Standby electrical (60 Hz) | 460 kWe | 450 kWe |
| Prime electrical (60 Hz) | 400 kWe | 400 kWe |
| Other recorded mechanical power (duty unspecified) | 510 kW | Not listed |
| Displacement | 12.54 L | 15 L |
| Configuration | L6 | L6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | Not listed | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | Euro Stage IIIA / U.S. EPA Tier 3 |
| Dry weight | Not listed | Not listed |
| Origin | China | United Kingdom |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Baudouin 6M21G8D0/S: Review the model record and available supporting documents
Perkins 2506C-E15TAG2: Review the model record and available supporting documents
Choosing between Baudouin 6M21G8D0/S and Perkins 2506C-E15TAG2
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.