Baudouin 6M31G660/5 vs MTU 12V1600G10
Compare Baudouin 6M31G660/5 and MTU 12V1600G10 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 18.5 L and 21 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Baudouin 6M31G660/5 | MTU 12V1600G10 |
|---|---|---|
| Standby electrical (50 Hz) | 528 kWe | 528 kWe |
| Prime electrical (50 Hz) | 480 kWe | 481 kWe |
| Standby electrical (60 Hz) | 660 kWe | 555 kWe |
| Prime electrical (60 Hz) | 600 kWe | 508 kWe |
| Displacement | 18.5 L | 21 L |
| Configuration | L6 | V12 |
| Cylinders | 6 | 12 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | U.S. EPA Tier 2 |
| Dry weight | Not listed | Not listed |
| Origin | France | Germany |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Baudouin 6M31G660/5: Review the model record and available supporting documents
MTU 12V1600G10: Review the model record and available supporting documents
Choosing between Baudouin 6M31G660/5 and MTU 12V1600G10
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.