Baudouin 6M31G9D3/5 vs Perkins 4006-23TAG3A
Compare Baudouin 6M31G9D3/5 and Perkins 4006-23TAG3A by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 18.5 L and 23 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Baudouin 6M31G9D3/5 | Perkins 4006-23TAG3A |
|---|---|---|
| Standby electrical (50 Hz) | 720 kWe | 718 kWe |
| Prime electrical (50 Hz) | 640 kWe | 641 kWe |
| Standby electrical (60 Hz) | Not listed | 755 kWe |
| Prime electrical (60 Hz) | Not listed | 680 kWe |
| Other recorded mechanical power (duty unspecified) | 800 kW | Not listed |
| Displacement | 18.5 L | 23 L |
| Configuration | L6 | V6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | China III | Unregulated |
| Dry weight | Not listed | Not listed |
| Origin | China | United Kingdom |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Baudouin 6M31G9D3/5: Review the model record and available supporting documents
Perkins 4006-23TAG3A: Review the model record and available supporting documents
Choosing between Baudouin 6M31G9D3/5 and Perkins 4006-23TAG3A
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.