Haifeng Machinery

Bergen B36:45V16 vs Wärtsilä 20V34SG

The Bergen B36:45V16 and Wärtsilä 20V34SG are both natural gas generator engines in a similar power class. Both are rated at roughly 12,041 kVA. Displacement is 732.9 L versus 726.5 L. The table below compares their full specifications side by side.

SpecificationBergen B36:45V16Wärtsilä 20V34SG
Headline rating11,838 kVA12,244 kVA
Standby (50 Hz)——
Prime (50 Hz)9,470 kWe9,795 kWe
Standby (60 Hz)——
Prime (60 Hz)—9,388 kWe
Displacement732.9 L726.5 L
ConfigurationV16V20
Cylinders1620
Rated speed750 RPM750 / 900 RPM
FuelNatural GasNatural Gas
CoolingLiquid-CooledLiquid-Cooled
EmissionsUnregulatedUnregulated
Dry weight150000 kg—
OriginNorwayFinland

Choosing between Bergen B36:45V16 and Wärtsilä 20V34SG

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing. The Wärtsilä 20V34SG has the higher headline kVA rating in this pair, but site conditions and duty cycle can still change the final recommendation.