CAMC Hanma HMT14F vs Caterpillar G3412C
Compare CAMC Hanma HMT14F and Caterpillar G3412C by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 13.67 L and 27 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | CAMC Hanma HMT14F | Caterpillar G3412C |
|---|---|---|
| Standby electrical (50 Hz) | 361 kWe | Not listed |
| Prime electrical (50 Hz) | 328 kWe | 374 kWe |
| Standby electrical (60 Hz) | Not listed | Not listed |
| Prime electrical (60 Hz) | Not listed | 423 kWe |
| Other recorded mechanical power (duty unspecified) | 328 kW | 374 kW |
| Displacement | 13.67 L | 27 L |
| Configuration | L6 | V12 |
| Cylinders | 6 | 12 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Natural Gas | Natural Gas |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | U.S. EPA Stationary |
| Dry weight | 1,100 kg | Not listed |
| Origin | China | United States |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
CAMC Hanma HMT14F: Review the model record and available supporting documents
Caterpillar G3412C: Review the model record and available supporting documents
Choosing between CAMC Hanma HMT14F and Caterpillar G3412C
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.