Caterpillar 3608 vs Googol QTAA20V-EG3200
Compare Caterpillar 3608 and Googol QTAA20V-EG3200 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 147.8 L and 107.5 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Caterpillar 3608 | Googol QTAA20V-EG3200 |
|---|---|---|
| Standby electrical (50 Hz) | 2,860 kWe | 2,860 kWe |
| Prime electrical (50 Hz) | 2,600 kWe | 2,600 kWe |
| Standby electrical (60 Hz) | 2,660 kWe | Not listed |
| Prime electrical (60 Hz) | 2,420 kWe | Not listed |
| Other recorded mechanical power (duty unspecified) | 2,600 kW | Not listed |
| Displacement | 147.8 L | 107.5 L |
| Configuration | V8 | V20 |
| Cylinders | 8 | 20 |
| Recorded engine speed | 1,000 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Air-Air |
| Recorded emissions classification | U.S. EPA Tier 2 | China National Stage III / Unregulated |
| Dry weight | Not listed | 7,550 kg |
| Origin | United States | China |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Caterpillar 3608: Review the model record and available supporting documents
Googol QTAA20V-EG3200: Review the model record and available supporting documents
Choosing between Caterpillar 3608 and Googol QTAA20V-EG3200
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.