Haifeng Machinery

Caterpillar CG170B-16 vs Cummins C1800N6CD

Compare Caterpillar CG170B-16 and Cummins C1800N6CD by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 70.8 L and 78 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationCaterpillar CG170B-16Cummins C1800N6CD
Standby electrical (50 Hz)Not listedNot listed
Prime electrical (50 Hz)1,840 kWeNot listed
Standby electrical (60 Hz)Not listedNot listed
Prime electrical (60 Hz)Not listed1,800 kWe
Other recorded mechanical power (duty unspecified)1,840 kWNot listed
Displacement70.8 L78 L
ConfigurationV16V12
Cylinders1612
Recorded engine speed1,500 RPM1,800 RPM
FuelNatural GasNatural Gas
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationUnregulatedNot listed
Dry weightNot listedNot listed
OriginGermanyUnited States

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Caterpillar CG170B-16: Review the model record and available supporting documents

Cummins C1800N6CD: Review the model record and available supporting documents

Choosing between Caterpillar CG170B-16 and Cummins C1800N6CD

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.

With your permission, we use analytics to improve engine search and understand which pages lead to enquiries. The catalog works without analytics.

Essential storage — always on

Remembers your choice for 180 days in this browser on this site.

Google Analytics and Vercel Analytics measure page views, search results and enquiry-link clicks. Our custom events exclude raw search text. A link click is not a submitted enquiry.