Cummins 4B3.9-G12 vs John Deere 3029TFG89

Compare Cummins 4B3.9-G12 and John Deere 3029TFG89 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 3.9 L and 2.9 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationCummins 4B3.9-G12John Deere 3029TFG89
Standby electrical (50 Hz)30 kWeNot listed
Prime electrical (50 Hz)25 kWeNot listed
Standby electrical (60 Hz)35 kWe30 kWe
Prime electrical (60 Hz)28 kWe29 kWe
Displacement3.9 L2.9 L
ConfigurationL4L3
Cylinders43
Recorded engine speed1,500 RPM1,800 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationUnregulatedU.S. EPA Tier 3
Dry weightNot listedNot listed
OriginChinaUnited States

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Cummins 4B3.9-G12: Review the model record and available supporting documents

John Deere 3029TFG89: Review the model record and available supporting documents

Choosing between Cummins 4B3.9-G12 and John Deere 3029TFG89

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.

With your permission, we use analytics to improve engine search and understand which pages lead to enquiries. The catalog works without analytics.

Essential storage — always on

Remembers your choice for 180 days in this browser on this site.

Google Analytics and Vercel Analytics measure page views, search results and enquiry-link clicks. Our custom events exclude raw search text. A link click is not a submitted enquiry.

Change your choice in the footer at any time. Turning analytics off reloads the page.