Compare Cummins 6ZTAA13-G2 and Lister Petter LP625SG1 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 13 L and 25.18 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationCummins 6ZTAA13-G2Lister Petter LP625SG1
Standby electrical (50 Hz)438 kWe436 kWe
Prime electrical (50 Hz)350 kWe400 kWe
Standby electrical (60 Hz)438 kWe504 kWe
Prime electrical (60 Hz)350 kWe460 kWe
Other recorded mechanical power (duty unspecified)Not listed484 kW
Displacement13 L25.18 L
ConfigurationL6L6
Cylinders66
Recorded engine speed1,500 RPM1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationUnregulatedEuro Stage III
Dry weightNot listedNot listed
OriginChinaUnited Kingdom

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Cummins 6ZTAA13-G2: Review the model record and available supporting documents

Lister Petter LP625SG1: Review the model record and available supporting documents

Choosing between Cummins 6ZTAA13-G2 and Lister Petter LP625SG1

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.