Cummins C200N6B vs PSI 10L T
Compare Cummins C200N6B and PSI 10L T by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 8.9 L and 9.73 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Cummins C200N6B | PSI 10L T |
|---|---|---|
| Standby electrical (50 Hz) | Not listed | 200 kWe |
| Prime electrical (50 Hz) | Not listed | 180 kWe |
| Standby electrical (60 Hz) | 200 kWe | 204 kWe |
| Prime electrical (60 Hz) | Not listed | 170 kWe |
| Other recorded mechanical power (duty unspecified) | 231.2 kW | 200 kW |
| Displacement | 8.9 L | 9.73 L |
| Configuration | L6 | L6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | 1,800 RPM | 1,800 RPM |
| Fuel | Natural Gas | Natural Gas |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | U.S. EPA Stationary | U.S. EPA Stationary |
| Dry weight | Not listed | 1,180 kg |
| Origin | United States | United States |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Cummins C200N6B: Review the model record and available supporting documents
PSI 10L T: Review the model record and available supporting documents
Choosing between Cummins C200N6B and PSI 10L T
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.