Cummins K38N-G7 vs Guascor G-48FL
Compare Cummins K38N-G7 and Guascor G-48FL by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 37.8 L and 47.9 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Cummins K38N-G7 | Guascor G-48FL |
|---|---|---|
| Standby electrical (50 Hz) | Not listed | Not listed |
| Prime electrical (50 Hz) | 700 kWe | 703 kWe |
| Standby electrical (60 Hz) | Not listed | Not listed |
| Prime electrical (60 Hz) | 700 kWe | 761 kWe |
| Other recorded mechanical power (duty unspecified) | 785 kW | Not listed |
| Displacement | 37.8 L | 47.9 L |
| Configuration | V12 | V16 |
| Cylinders | 12 | 16 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Natural Gas | Natural Gas |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | Unregulated |
| Dry weight | Not listed | Not listed |
| Origin | China | Spain |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Cummins K38N-G7: Review the model record and available supporting documents
Guascor G-48FL: Review the model record and available supporting documents
Choosing between Cummins K38N-G7 and Guascor G-48FL
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.