Cummins KTA38-G7E vs Yuchai YC12VTD1350-D30
Compare Cummins KTA38-G7E and Yuchai YC12VTD1350-D30 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 38 L and 39.2 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Cummins KTA38-G7E | Yuchai YC12VTD1350-D30 |
|---|---|---|
| Standby electrical (50 Hz) | 900 kWe | 900 kWe |
| Prime electrical (50 Hz) | 850 kWe | 800 kWe |
| Standby electrical (60 Hz) | Not listed | Not listed |
| Prime electrical (60 Hz) | Not listed | Not listed |
| Displacement | 38 L | 39.2 L |
| Configuration | V12 | V12 |
| Cylinders | 12 | 12 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | China National Stage III / Unregulated | China National Stage III / Unregulated |
| Dry weight | Not listed | Not listed |
| Origin | China | China |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Cummins KTA38-G7E: Review the model record and available supporting documents
Yuchai YC12VTD1350-D30: Review the model record and available supporting documents
Choosing between Cummins KTA38-G7E and Yuchai YC12VTD1350-D30
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.