Haifeng Machinery

Cummins KTA50-G15X vs Perkins 5012C-E46TAG6

Compare Cummins KTA50-G15X and Perkins 5012C-E46TAG6 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 50.3 L and 46 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationCummins KTA50-G15XPerkins 5012C-E46TAG6
Standby electrical (50 Hz)1,500 kWeNot listed
Prime electrical (50 Hz)1,340 kWeNot listed
Standby electrical (60 Hz)Not listed1,501 kWe
Prime electrical (60 Hz)Not listed1,351 kWe
Displacement50.3 L46 L
ConfigurationV16V12
Cylinders1612
Recorded engine speed1,500 RPM1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationUnregulatedU.S. EPA Tier 2
Dry weightNot listedNot listed
OriginChinaUnited States

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Cummins KTA50-G15X: Review the model record and available supporting documents

Perkins 5012C-E46TAG6: Review the model record and available supporting documents

Choosing between Cummins KTA50-G15X and Perkins 5012C-E46TAG6

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.