Haifeng Machinery

Cummins KTA50-G16B vs Lister Petter LP1265EG18

Compare Cummins KTA50-G16B and Lister Petter LP1265EG18 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 50.3 L and 64.5 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationCummins KTA50-G16BLister Petter LP1265EG18
Standby electrical (50 Hz)1,650 kWeNot listed
Prime electrical (50 Hz)1,600 kWeNot listed
Standby electrical (60 Hz)Not listed1,650 kWe
Prime electrical (60 Hz)Not listed1,500 kWe
Other recorded mechanical power (duty unspecified)Not listed1,780 kW
Displacement50.3 L64.5 L
ConfigurationV16V12
Cylinders1612
Recorded engine speed1,500 RPM1,800 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationUnregulatedEuro Stage III
Dry weightNot listedNot listed
OriginChinaUnited Kingdom

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Cummins KTA50-G16B: Review the model record and available supporting documents

Lister Petter LP1265EG18: Review the model record and available supporting documents

Choosing between Cummins KTA50-G16B and Lister Petter LP1265EG18

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.