Cummins NTAA855-G7A vs Hyundai DP126CBK
Compare Cummins NTAA855-G7A and Hyundai DP126CBK by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 14 L and 11.1 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Cummins NTAA855-G7A | Hyundai DP126CBK |
|---|---|---|
| Standby electrical (50 Hz) | 360 kWe | 356 kWe |
| Prime electrical (50 Hz) | 330 kWe | 321 kWe |
| Standby electrical (60 Hz) | Not listed | Not listed |
| Prime electrical (60 Hz) | Not listed | Not listed |
| Displacement | 14 L | 11.1 L |
| Configuration | L6 | L6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | U.S. EPA Tier 2 |
| Dry weight | Not listed | Not listed |
| Origin | China | South Korea |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Cummins NTAA855-G7A: Review the model record and available supporting documents
Hyundai DP126CBK: Review the model record and available supporting documents
Choosing between Cummins NTAA855-G7A and Hyundai DP126CBK
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.