Cummins NTAA855-G7A vs Scania DC13 505A 450
Compare Cummins NTAA855-G7A and Scania DC13 505A 450 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 14 L and 13 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Cummins NTAA855-G7A | Scania DC13 505A 450 |
|---|---|---|
| Standby electrical (50 Hz) | 360 kWe | Not listed |
| Prime electrical (50 Hz) | 330 kWe | 360 kWe |
| Standby electrical (60 Hz) | Not listed | Not listed |
| Prime electrical (60 Hz) | Not listed | 360 kWe |
| Displacement | 14 L | 13 L |
| Configuration | L6 | L6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | Euro Stage V |
| Dry weight | Not listed | Not listed |
| Origin | China | Sweden |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Cummins NTAA855-G7A: Review the model record and available supporting documents
Scania DC13 505A 450: Review the model record and available supporting documents
Choosing between Cummins NTAA855-G7A and Scania DC13 505A 450
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.