Haifeng Machinery

Cummins QSL9-G5 vs Weichai WP10D264E350

Compare Cummins QSL9-G5 and Weichai WP10D264E350 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 8.8 L and 10 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationCummins QSL9-G5Weichai WP10D264E350
Standby electrical (50 Hz)240 kWe238 kWe
Prime electrical (50 Hz)220 kWe216 kWe
Standby electrical (60 Hz)275 kWeNot listed
Prime electrical (60 Hz)250 kWeNot listed
Displacement8.8 L10 L
ConfigurationL6L6
Cylinders66
Recorded engine speed1,800 RPM1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationU.S. EPA Tier 3China National Stage III / Unregulated
Dry weightNot listedNot listed
OriginUnited StatesChina

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Cummins QSL9-G5: Review the model record and available supporting documents

Weichai WP10D264E350: Review the model record and available supporting documents

Choosing between Cummins QSL9-G5 and Weichai WP10D264E350

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.

With your permission, we use analytics to improve engine search and understand which pages lead to enquiries. The catalog works without analytics.

Essential storage — always on

Remembers your choice for 180 days in this browser on this site.

Google Analytics and Vercel Analytics measure page views, search results and enquiry-link clicks. Our custom events exclude raw search text. A link click is not a submitted enquiry.

Change your choice in the footer at any time. Turning analytics off reloads the page.