Haifeng Machinery

Cummins QST30G2 vs MTU MTU 12V2000 G65

Compare Cummins QST30G2 and MTU MTU 12V2000 G65 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 30 L and 23.88 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationCummins QST30G2MTU MTU 12V2000 G65
Standby electrical (50 Hz)688 kWe689 kWe
Prime electrical (50 Hz)643 kWe626 kWe
Standby electrical (60 Hz)800 kWeNot listed
Prime electrical (60 Hz)740 kWeNot listed
Other recorded mechanical power (duty unspecified)895 kWNot listed
Displacement30 L23.88 L
ConfigurationV12V12
Cylinders1212
Recorded engine speedNot listed1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationUnregulatedUnregulated
Dry weightNot listedNot listed
OriginUnited StatesGermany

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Cummins QST30G2: Review the model record and available supporting documents

MTU MTU 12V2000 G65: Review the model record and available supporting documents

Choosing between Cummins QST30G2 and MTU MTU 12V2000 G65

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.

With your permission, we use analytics to improve engine search and understand which pages lead to enquiries. The catalog works without analytics.

Essential storage — always on

Remembers your choice for 180 days in this browser on this site.

Google Analytics and Vercel Analytics measure page views, search results and enquiry-link clicks. Our custom events exclude raw search text. A link click is not a submitted enquiry.

Change your choice in the footer at any time. Turning analytics off reloads the page.