Haifeng Machinery

Deutz F3L912 vs Perkins 404D-22TG

The Deutz F3L912 and Perkins 404D-22TG are both diesel generator engines in a similar power class. Both are rated at roughly 30 kVA. Displacement is 2.828 L versus 2.2 L. The table below compares their full specifications side by side.

SpecificationDeutz F3L912Perkins 404D-22TG
Headline rating29 kVA30 kVA
Standby (50 Hz)23.4 kWe24 kWe
Prime (50 Hz)21.6 kWe22 kWe
Standby (60 Hz)27 kWe29 kWe
Prime (60 Hz)25.2 kWe26 kWe
Displacement2.828 L2.2 L
ConfigurationL3L4
Cylinders34
Rated speed1,500 / 1,800 RPM1,500 / 1,800 RPM
FuelDieselDiesel
CoolingAir-CooledLiquid-Cooled
EmissionsUnregulatedU.S. EPA Tier 4 Interim
Dry weight
OriginGermanyChina

Choosing between Deutz F3L912 and Perkins 404D-22TG

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing. The Perkins 404D-22TG has the higher headline kVA rating in this pair, but site conditions and duty cycle can still change the final recommendation.