FPT C87TEVP04.00 vs Volvo Penta TAD1383VE
Compare FPT C87TEVP04.00 and Volvo Penta TAD1383VE by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 8.7 L and 12.8 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | FPT C87TEVP04.00 | Volvo Penta TAD1383VE |
|---|---|---|
| Standby electrical (50 Hz) | Not listed | Not listed |
| Prime electrical (50 Hz) | Not listed | Not listed |
| Standby electrical (60 Hz) | 294.3 kWe | 292 kWe |
| Prime electrical (60 Hz) | 266.4 kWe | 266 kWe |
| Other recorded mechanical power (duty unspecified) | Not listed | 314 kW |
| Displacement | 8.7 L | 12.8 L |
| Configuration | L6 | L6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | 1,800 RPM | 1,800 RPM |
| Fuel | Diesel | Diesel/HVO |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | U.S. EPA Final Tier 4 | U.S. EPA Final Tier 4 |
| Dry weight | Not listed | Not listed |
| Origin | Italy | Sweden |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
FPT C87TEVP04.00: Review the model record and available supporting documents
Volvo Penta TAD1383VE: Review the model record and available supporting documents
Choosing between FPT C87TEVP04.00 and Volvo Penta TAD1383VE
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.