Guascor G-36FL vs MAN E 3262 LE252
Compare Guascor G-36FL and MAN E 3262 LE252 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 35.9 L and 25.8 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Guascor G-36FL | MAN E 3262 LE252 |
|---|---|---|
| Standby electrical (50 Hz) | Not listed | Not listed |
| Prime electrical (50 Hz) | 529 kWe | 509 kWe |
| Standby electrical (60 Hz) | Not listed | Not listed |
| Prime electrical (60 Hz) | 577 kWe | 509 kWe |
| Other recorded mechanical power (duty unspecified) | Not listed | 530 kW |
| Displacement | 35.9 L | 25.8 L |
| Configuration | V12 | V12 |
| Cylinders | 12 | 12 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Natural Gas | Natural Gas |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | Unregulated |
| Dry weight | Not listed | Not listed |
| Origin | Spain | Germany |
MAN E 3262 LE252: Electrical output includes catalog estimates. Check the calculation basis and source document on the model page; these are not verified complete-generator ratings. Rating details
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Guascor G-36FL: Review the model record and available supporting documents
MAN E 3262 LE252: Review the model record and available supporting documents
Choosing between Guascor G-36FL and MAN E 3262 LE252
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.