Hyundai DP054CC vs SDEC 6HTAA6.5-G23
Compare Hyundai DP054CC and SDEC 6HTAA6.5-G23 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 5 L and 6.5 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Hyundai DP054CC | SDEC 6HTAA6.5-G23 |
|---|---|---|
| Standby electrical (50 Hz) | 170 kWe | 167 kWe |
| Prime electrical (50 Hz) | 160 kWe | 151 kWe |
| Standby electrical (60 Hz) | 187 kWe | 167 kWe |
| Prime electrical (60 Hz) | 175 kWe | 151 kWe |
| Displacement | 5 L | 6.5 L |
| Configuration | L4 | L6 |
| Cylinders | 4 | 6 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | China National Stage III / Unregulated |
| Dry weight | Not listed | Not listed |
| Origin | South Korea | China |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Hyundai DP054CC: Review the model record and available supporting documents
SDEC 6HTAA6.5-G23: Review the model record and available supporting documents
Choosing between Hyundai DP054CC and SDEC 6HTAA6.5-G23
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.