Hyundai DP054CCP vs SDEC SC7H250D2
Compare Hyundai DP054CCP and SDEC SC7H250D2 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 5 L and 7 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Hyundai DP054CCP | SDEC SC7H250D2 |
|---|---|---|
| Standby electrical (50 Hz) | 165 kWe | 167 kWe |
| Prime electrical (50 Hz) | 160 kWe | 151 kWe |
| Standby electrical (60 Hz) | 177 kWe | Not listed |
| Prime electrical (60 Hz) | 175 kWe | Not listed |
| Displacement | 5 L | 7 L |
| Configuration | L4 | L6 |
| Cylinders | 4 | 6 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | U.S. EPA Final Tier 4 | China National Stage II / Unregulated |
| Dry weight | Not listed | Not listed |
| Origin | South Korea | China |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Hyundai DP054CCP: Review the model record and available supporting documents
SDEC SC7H250D2: Review the model record and available supporting documents
Choosing between Hyundai DP054CCP and SDEC SC7H250D2
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.