Haifeng Machinery

Kohler KDI3404TCR vs Mahindra 4905 GMA-C2

Compare Kohler KDI3404TCR and Mahindra 4905 GMA-C2 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 3.4 L and 3.532 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationKohler KDI3404TCRMahindra 4905 GMA-C2
Standby electrical (50 Hz)50 kWe50 kWe
Prime electrical (50 Hz)45 kWe45 kWe
Standby electrical (60 Hz)60 kWeNot listed
Prime electrical (60 Hz)54 kWeNot listed
Displacement3.4 L3.532 L
ConfigurationL4L4
Cylinders44
Recorded engine speed1,800 RPM1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationU.S. EPA Final Tier 4Unregulated
Dry weightNot listedNot listed
OriginItalyIndia

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Kohler KDI3404TCR: Review the model record and available supporting documents

Mahindra 4905 GMA-C2: Review the model record and available supporting documents

Choosing between Kohler KDI3404TCR and Mahindra 4905 GMA-C2

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.

With your permission, we use analytics to improve engine search and understand which pages lead to enquiries. The catalog works without analytics.

Essential storage — always on

Remembers your choice for 180 days in this browser on this site.

Google Analytics and Vercel Analytics measure page views, search results and enquiry-link clicks. Our custom events exclude raw search text. A link click is not a submitted enquiry.

Change your choice in the footer at any time. Turning analytics off reloads the page.