Lister Petter LP613EG1 vs Volvo Penta TAD1382GE
Compare Lister Petter LP613EG1 and Volvo Penta TAD1382GE by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 12.8 L and 12.8 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Lister Petter LP613EG1 | Volvo Penta TAD1382GE |
|---|---|---|
| Standby electrical (50 Hz) | 352 kWe | 352 kWe |
| Prime electrical (50 Hz) | 320 kWe | 320 kWe |
| Standby electrical (60 Hz) | 384 kWe | Not listed |
| Prime electrical (60 Hz) | 360 kWe | Not listed |
| Other recorded mechanical power (duty unspecified) | 385 kW | 374 kW |
| Displacement | 12.8 L | 12.8 L |
| Configuration | L6 | L6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Euro Stage III | Euro Stage V |
| Dry weight | Not listed | Not listed |
| Origin | United Kingdom | Sweden |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Lister Petter LP613EG1: Review the model record and available supporting documents
Volvo Penta TAD1382GE: Review the model record and available supporting documents
Choosing between Lister Petter LP613EG1 and Volvo Penta TAD1382GE
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.