Haifeng Machinery

Lister Petter SA430G1 vs SDEC 4Z2.7-G11

Compare Lister Petter SA430G1 and SDEC 4Z2.7-G11 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 3 L and 2.7 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationLister Petter SA430G1SDEC 4Z2.7-G11
Standby electrical (50 Hz)22 kWe22 kWe
Prime electrical (50 Hz)20 kWe20 kWe
Standby electrical (60 Hz)24.2 kWeNot listed
Prime electrical (60 Hz)22 kWeNot listed
Other recorded mechanical power (duty unspecified)26 kWNot listed
Displacement3 L2.7 L
ConfigurationL4L4
Cylinders44
Recorded engine speed1,500 RPM1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationEuro Stage IIChina National Stage II / Unregulated
Dry weightNot listedNot listed
OriginUnited KingdomChina

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Lister Petter SA430G1: Review the model record and available supporting documents

SDEC 4Z2.7-G11: Review the model record and available supporting documents

Choosing between Lister Petter SA430G1 and SDEC 4Z2.7-G11

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.