Mitsubishi S16R-A2PTAW vs Weichai 16M33D1800E310
Compare Mitsubishi S16R-A2PTAW and Weichai 16M33D1800E310 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 65.37 L and 52.8 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Mitsubishi S16R-A2PTAW | Weichai 16M33D1800E310 |
|---|---|---|
| Standby electrical (50 Hz) | 1,624.8 kWe | 1,620 kWe |
| Prime electrical (50 Hz) | 1,477.6 kWe | 1,512 kWe |
| Standby electrical (60 Hz) | Not listed | 1,728 kWe |
| Prime electrical (60 Hz) | Not listed | 1,575 kWe |
| Displacement | 65.37 L | 52.8 L |
| Configuration | V16 | V16 |
| Cylinders | 16 | 16 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | U.S. EPA Tier 2 | China National Stage III / Unregulated |
| Dry weight | 6,530 kg | 5,200 kg |
| Origin | Japan | China |
Mitsubishi S16R-A2PTAW: Electrical output includes catalog estimates. Check the calculation basis and source document on the model page; these are not verified complete-generator ratings. Rating details
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Mitsubishi S16R-A2PTAW: Review the model record and available supporting documents
Weichai 16M33D1800E310: Review the model record and available supporting documents
Choosing between Mitsubishi S16R-A2PTAW and Weichai 16M33D1800E310
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.