The Generator EngineEncyclopedia

Mitsubishi S16R-PTAR-C(新) vs Perkins 4016TAG1A

The Mitsubishi S16R-PTAR-C(新) and Perkins 4016TAG1A are both diesel generator engines in a similar power class. Both are rated at roughly 2,015 kVA. Displacement is 46.56 L versus 61.1 L. The table below compares their full specifications side by side.

SpecificationMitsubishi S16R-PTAR-C(新)Perkins 4016TAG1A
Headline rating2,001 kVA2,028 kVA
Standby (50 Hz)1,601.1 kWe1,622 kWe
Prime (50 Hz)1,455.3 kWe1,476 kWe
Standby (60 Hz)
Prime (60 Hz)
Displacement46.56 L61.1 L
ConfigurationV16V16
Cylinders1616
Rated speed1,500 RPM1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
EmissionsChina National Stage III / UnregulatedUnregulated
Dry weight
OriginChinaUnited Kingdom