Volvo Penta TAD1381VE vs Weichai WP10D264E200
Compare Volvo Penta TAD1381VE and Weichai WP10D264E200 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 12.8 L and 10 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Volvo Penta TAD1381VE | Weichai WP10D264E200 |
|---|---|---|
| Standby electrical (50 Hz) | Not listed | 238 kWe |
| Prime electrical (50 Hz) | Not listed | 216 kWe |
| Standby electrical (60 Hz) | 238 kWe | 238 kWe |
| Prime electrical (60 Hz) | 216 kWe | 216 kWe |
| Other recorded mechanical power (duty unspecified) | 256 kW | Not listed |
| Displacement | 12.8 L | 10 L |
| Configuration | L6 | L6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | 1,800 RPM | 1,500 RPM |
| Fuel | Diesel/HVO | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | U.S. EPA Final Tier 4 | China National Stage II / Unregulated |
| Dry weight | Not listed | Not listed |
| Origin | Sweden | China |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Volvo Penta TAD1381VE: Review the model record and available supporting documents
Weichai WP10D264E200: Review the model record and available supporting documents
Choosing between Volvo Penta TAD1381VE and Weichai WP10D264E200
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.