Baudouin 16M33G6N0/5 vs Perkins 4012-46TWG2A
Compare Baudouin 16M33G6N0/5 and Perkins 4012-46TWG2A by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 52.8 L and 45.8 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Baudouin 16M33G6N0/5 | Perkins 4012-46TWG2A |
|---|---|---|
| Standby electrical (50 Hz) | Not listed | 1,108 kWe |
| Prime electrical (50 Hz) | 1,100 kWe | 1,000 kWe |
| Standby electrical (60 Hz) | Not listed | 1,108 kWe |
| Prime electrical (60 Hz) | 1,100 kWe | 1,002 kWe |
| Other recorded mechanical power (duty unspecified) | Not listed | 1,000 kW |
| Displacement | 52.8 L | 45.8 L |
| Configuration | V16 | V12 |
| Cylinders | 16 | 12 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Natural Gas | Natural Gas |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | Unregulated |
| Dry weight | Not listed | Not listed |
| Origin | France | United Kingdom |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Baudouin 16M33G6N0/5: Review the model record and available supporting documents
Perkins 4012-46TWG2A: Review the model record and available supporting documents
Choosing between Baudouin 16M33G6N0/5 and Perkins 4012-46TWG2A
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.