Perkins
Perkins 4012-46TWG2A
4000 Series Gas
Perkins 4012-46TWG2A — 45.8 L V12 (160 × 190 mm) turbocharged spark-ignited natural-gas/biogas engine (Perkins 4000 Series Gas). 750–1000 kWe at 1500 rpm / 50 Hz, for CHP / power generation.
Overhaul & repair parts- Supporting documents
- 3 documents · 3 datasheets
- Last updated
- 2026-06-09
- Package route
- gas generator sets
- Standby Power · 50 Hz
- 1,385 kVA
- Electrical Output
- 1,108 kWe
- Cylinders
- V12
- Displacement
- 45.8 L
- Rated Speed
- 1,500 / 1,800 RPM
Power Ratings
kWm = mechanical shaft power · kWe = electrical output · kVA = kWe ÷ 0.8 pf
50 Hz1500 RPM
| kWm | kWe | kVA | |
|---|---|---|---|
| Prime Power | 1113.3 | 1000 | 1250 |
| Standby Power | 1231.1 | 1108 | 1385 |
60 Hz1800 RPM
| kWm | kWe | kVA | |
|---|---|---|---|
| Prime Power | 1113.3 | 1002 | 1252.5 |
| Standby Power | 1231.1 | 1108 | 1385 |
Ask about Perkins 4012-46TWG2A
Choose parts / service or sourcing. Your message includes this model and page link.
Perkins 4012-46TWG2A overhaul & repair parts
Already running a Perkins 4012-46TWG2A? Start with the parts you need, then send your nameplate so we can help check the right references for your engine.
These categories have model-related records. Part numbers need further checking before we display them here.
Let’s identify the right parts.
The model is the starting point. Serial numbers and build configurations can change which parts fit.
- Take a clear photo of the engine nameplate.
- Tell us what needs repair or replacement.
- Send both in WhatsApp to start a fitment check.
Opens WhatsApp with 4012-46TWG2A and your selected categories included. Attach your photos there.
Perkins 4012-46TWG2A generator set context
The Perkins 4012-46TWG2A is listed here as a natural gas generator-drive engine for 50 Hz and 60 Hz generator sets, with a headline 1,385 kVA / 1,108 kWe / standby rating. Use this page to compare the published engine output, electrical kWe/kVA ratings, emissions level, datasheet availability, and neighboring models before specifying an alternator, controller, enclosure, voltage, and compliance package.
Also searched as
Technical Specifications
| Brand | Perkins |
| Model | 4012-46TWG2A |
| Series | 4000 Series Gas |
| Configuration | V12 |
| Cylinders | 12 |
| Displacement | 45.8 L |
| Fuel Type | Natural Gas |
| Ignition Type | Spark Ignition |
| Cooling Method | Liquid-Cooled |
| Emissions Standard | Unregulated |
| Country of Origin | United Kingdom |
Frequently asked questions
What is the power output of the Perkins 4012-46TWG2A?
The Perkins 4012-46TWG2A is rated at 1,385 kVA standby / 1,250 kVA prime at 50 Hz (1,500 rpm); and 1,385 kVA standby / 1,253 kVA prime at 60 Hz (1,800 rpm).
Does the 4012-46TWG2A run at 50 Hz or 60 Hz?
The Perkins 4012-46TWG2A is available for both 50 Hz (1,500 rpm) and 60 Hz (1,800 rpm).
What fuel does the Perkins 4012-46TWG2A use?
The Perkins 4012-46TWG2A is a Natural Gas generator-set engine.
What is the displacement and cylinder configuration of the 4012-46TWG2A?
The Perkins 4012-46TWG2A is a V12 (12-cylinder) engine with a displacement of 45.8 L.
What is the catalog status of the Perkins 4012-46TWG2A?
The Perkins 4012-46TWG2A is marked active in this database. Confirm current production and availability with the manufacturer; catalog status is not a live supply check.
Are reference documents available for the 4012-46TWG2A?
This page links reference documents for the Perkins 4012-46TWG2A. Check each document's title, model coverage, revision and rating conditions before using it for selection.