Haifeng Machinery

Cummins 4BT3.9-G1 vs Perkins 1103A-33TG1

Compare Cummins 4BT3.9-G1 and Perkins 1103A-33TG1 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 3.9 L and 3.3 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationCummins 4BT3.9-G1Perkins 1103A-33TG1
Standby electrical (50 Hz)40 kWe40 kWe
Prime electrical (50 Hz)32 kWe36 kWe
Standby electrical (60 Hz)Not listed47 kWe
Prime electrical (60 Hz)Not listed43 kWe
Displacement3.9 L3.3 L
ConfigurationL4L3
Cylinders43
Recorded engine speed1,500 RPM1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationUnregulatedUnregulated
Dry weightNot listedNot listed
OriginChinaUnited Kingdom

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Cummins 4BT3.9-G1: Review the model record and available supporting documents

Perkins 1103A-33TG1: Review the model record and available supporting documents

Choosing between Cummins 4BT3.9-G1 and Perkins 1103A-33TG1

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.