Haifeng Machinery

Cummins B6.7CS4GT1 vs Weichai WP6D167E200

Compare Cummins B6.7CS4GT1 and Weichai WP6D167E200 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 6.7 L and 6.1 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationCummins B6.7CS4GT1Weichai WP6D167E200
Standby electrical (50 Hz)150 kWe150 kWe
Prime electrical (50 Hz)150 kWeNot listed
Standby electrical (60 Hz)Not listed162 kWe
Prime electrical (60 Hz)Not listed148 kWe
Other recorded mechanical power (duty unspecified)188 kW180 kW
Displacement6.7 L6.1 L
ConfigurationL6L6
Cylinders66
Recorded engine speed1,500 RPM1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationChina IVChina National Stage II / Unregulated
Dry weightNot listed680 kg
OriginChinaChina

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Cummins B6.7CS4GT1: Review the model record and available supporting documents

Weichai WP6D167E200: Review the model record and available supporting documents

Choosing between Cummins B6.7CS4GT1 and Weichai WP6D167E200

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.

With your permission, we use analytics to improve engine search and understand which pages lead to enquiries. The catalog works without analytics.

Essential storage — always on

Remembers your choice for 180 days in this browser on this site.

Google Analytics and Vercel Analytics measure page views, search results and enquiry-link clicks. Our custom events exclude raw search text. A link click is not a submitted enquiry.

Change your choice in the footer at any time. Turning analytics off reloads the page.