Cummins GTA855E vs Jichai JC15T1
Compare Cummins GTA855E and Jichai JC15T1 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 14 L and 15.2 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Cummins GTA855E | Jichai JC15T1 |
|---|---|---|
| Standby electrical (50 Hz) | Not listed | Not listed |
| Prime electrical (50 Hz) | Not listed | 250 kWe |
| Standby electrical (60 Hz) | 245 kWe | Not listed |
| Prime electrical (60 Hz) | 225 kWe | Not listed |
| Other recorded mechanical power (duty unspecified) | 286 kW | 300 kW |
| Displacement | 14 L | 15.2 L |
| Configuration | L6 | L6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | 1,800 RPM | 1,500 RPM |
| Fuel | Natural Gas | Natural Gas |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | U.S. EPA Stationary | China III (GB20891) |
| Dry weight | Not listed | Not listed |
| Origin | United States | China |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Cummins GTA855E: Review the model record and available supporting documents
Jichai JC15T1: Review the model record and available supporting documents
Choosing between Cummins GTA855E and Jichai JC15T1
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.