Cummins KTA50-G12A vs Mitsubishi S12R-PTAA2
Compare Cummins KTA50-G12A and Mitsubishi S12R-PTAA2 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 50.3 L and 49.03 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Cummins KTA50-G12A | Mitsubishi S12R-PTAA2 |
|---|---|---|
| Standby electrical (50 Hz) | 1,280 kWe | 1,296.9 kWe |
| Prime electrical (50 Hz) | 1,100 kWe | 1,182.6 kWe |
| Standby electrical (60 Hz) | 1,430 kWe | 1,469.7 kWe |
| Prime electrical (60 Hz) | 1,220 kWe | 1,335.6 kWe |
| Displacement | 50.3 L | 49.03 L |
| Configuration | V16 | V12 |
| Cylinders | 16 | 12 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | Unregulated |
| Dry weight | Not listed | Not listed |
| Origin | China | Japan |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Cummins KTA50-G12A: Review the model record and available supporting documents
Mitsubishi S12R-PTAA2: Review the model record and available supporting documents
Choosing between Cummins KTA50-G12A and Mitsubishi S12R-PTAA2
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.