Haifeng Machinery

Cummins KTA50G20 vs Weichai 12M33D1240E310

Compare Cummins KTA50G20 and Weichai 12M33D1240E310 by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 50 L and 39.6 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationCummins KTA50G20Weichai 12M33D1240E310
Standby electrical (50 Hz)1,116 kWe1,116 kWe
Prime electrical (50 Hz)1,020 kWe1,017 kWe
Standby electrical (60 Hz)1,195 kWeNot listed
Prime electrical (60 Hz)1,085 kWeNot listed
Other recorded mechanical power (duty unspecified)1,306 kWNot listed
Displacement50 L39.6 L
ConfigurationV16V12
Cylinders1612
Recorded engine speedNot listed1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationUnregulatedChina National Stage III / Unregulated
Dry weightNot listed3,527 kg
OriginIndiaChina

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Cummins KTA50G20: Review the model record and available supporting documents

Weichai 12M33D1240E310: Review the model record and available supporting documents

Choosing between Cummins KTA50G20 and Weichai 12M33D1240E310

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.

With your permission, we use analytics to improve engine search and understand which pages lead to enquiries. The catalog works without analytics.

Essential storage — always on

Remembers your choice for 180 days in this browser on this site.

Google Analytics and Vercel Analytics measure page views, search results and enquiry-link clicks. Our custom events exclude raw search text. A link click is not a submitted enquiry.

Change your choice in the footer at any time. Turning analytics off reloads the page.