Haifeng Machinery

Cummins QSK50-G4 vs Yuchai YC12VC2070-D31

Compare Cummins QSK50-G4 and Yuchai YC12VC2070-D31 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 50.3 L and 79.17 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.

SpecificationCummins QSK50-G4Yuchai YC12VC2070-D31
Standby electrical (50 Hz)1,360 kWe1,350 kWe
Prime electrical (50 Hz)1,232 kWe1,200 kWe
Standby electrical (60 Hz)1,500 kWeNot listed
Prime electrical (60 Hz)1,365 kWeNot listed
Displacement50.3 L79.17 L
ConfigurationV16V12
Cylinders1612
Recorded engine speed1,500 RPM1,500 RPM
FuelDieselDiesel
CoolingLiquid-CooledLiquid-Cooled
Recorded emissions classificationU.S. EPA Tier 2China National Stage III / Unregulated
Dry weightNot listedNot listed
OriginUnited StatesChina

Compare matching ratings

Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.

An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.

Cummins QSK50-G4: Review the model record and available supporting documents

Yuchai YC12VC2070-D31: Review the model record and available supporting documents

Choosing between Cummins QSK50-G4 and Yuchai YC12VC2070-D31

Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.