Detroit Diesel 12V71 vs Perkins 1506AE88TAG2
Compare Detroit Diesel 12V71 and Perkins 1506AE88TAG2 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 14 L and 8.8 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Detroit Diesel 12V71 | Perkins 1506AE88TAG2 |
|---|---|---|
| Standby electrical (50 Hz) | 210 kWe | 206 kWe |
| Prime electrical (50 Hz) | 190 kWe | 185 kWe |
| Standby electrical (60 Hz) | 250 kWe | 218 kWe |
| Prime electrical (60 Hz) | 225 kWe | 198 kWe |
| Other recorded mechanical power (duty unspecified) | Not listed | 237 kW |
| Displacement | 14 L | 8.8 L |
| Configuration | V12 | L6 |
| Cylinders | 12 | 6 |
| Recorded engine speed | 1,800 RPM | Not listed |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | Unregulated |
| Dry weight | Not listed | Not listed |
| Origin | United States | United States |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Detroit Diesel 12V71: Review the model record and available supporting documents
Perkins 1506AE88TAG2: Review the model record and available supporting documents
Choosing between Detroit Diesel 12V71 and Perkins 1506AE88TAG2
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.