Deutz TCG 2015 V6 vs PSI 11L
Compare Deutz TCG 2015 V6 and PSI 11L by catalog output, operating duty, frequency and engine specifications. Their listed displacements are 11.9 L and 11.05 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Deutz TCG 2015 V6 | PSI 11L |
|---|---|---|
| Standby electrical (50 Hz) | Not listed | 175 kWe |
| Prime electrical (50 Hz) | Not listed | 150 kWe |
| Standby electrical (60 Hz) | Not listed | 200 kWe |
| Prime electrical (60 Hz) | 171 kWe | 175 kWe |
| Other recorded mechanical power (duty unspecified) | 180 kW | 180 kW |
| Displacement | 11.9 L | 11.05 L |
| Configuration | V6 | L6 |
| Cylinders | 6 | 6 |
| Recorded engine speed | 1,800 RPM | 1,800 RPM |
| Fuel | Natural Gas | Natural Gas |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Unregulated | U.S. EPA Stationary |
| Dry weight | Not listed | 1,179 kg |
| Origin | Germany | United States |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Deutz TCG 2015 V6: Review the model record and available supporting documents
PSI 11L: Review the model record and available supporting documents
Choosing between Deutz TCG 2015 V6 and PSI 11L
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.