Hyundai DP054CCV vs Lister Petter LP665G3
Compare Hyundai DP054CCV and Lister Petter LP665G3 by recorded output, operating duty, frequency and engine specifications. Their listed displacements are 5 L and 6.5 L, respectively. Start with the same duty and frequency, then check each model’s source and package conditions. These records alone do not establish interchangeability.
| Specification | Hyundai DP054CCV | Lister Petter LP665G3 |
|---|---|---|
| Standby electrical (50 Hz) | 165 kWe | 165 kWe |
| Prime electrical (50 Hz) | 160 kWe | 150 kWe |
| Standby electrical (60 Hz) | 177 kWe | 165 kWe |
| Prime electrical (60 Hz) | 175 kWe | 150 kWe |
| Other recorded mechanical power (duty unspecified) | Not listed | 176 kW |
| Displacement | 5 L | 6.5 L |
| Configuration | L4 | L6 |
| Cylinders | 4 | 6 |
| Recorded engine speed | 1,500 RPM | 1,500 RPM |
| Fuel | Diesel | Diesel |
| Cooling | Liquid-Cooled | Liquid-Cooled |
| Recorded emissions classification | Euro Stage V | Euro Stage II |
| Dry weight | Not listed | Not listed |
| Origin | South Korea | United Kingdom |
Compare matching ratings
Read across a row to compare the same operating duty and frequency. kWe is electrical output; mechanical kW is power at the engine shaft. kVA is apparent electrical power and is shown only when kWe is missing, without converting it. “Not listed” means the record lacks that rating, not zero output. Continuous and prime duties are kept separate. Check source documents, units and site conditions before comparing values.
An emissions classification in the catalog is not proof of certification for your engine or installation. Confirm the exact model, applicable documents and generator configuration.
Hyundai DP054CCV: Review the model record and available supporting documents
Lister Petter LP665G3: Review the model record and available supporting documents
Choosing between Hyundai DP054CCV and Lister Petter LP665G3
Use this comparison as an engineering shortlist, then confirm the complete generator package against load profile, voltage, 50/60 Hz frequency, duty class, emissions rules, cooling margin, altitude, ambient temperature, enclosure design, controller features, and alternator sizing.